Pick-and-Place
This tutorial will walk you through using the LumenPnP in the back of E15-043.
The version of this machine is v3.x.
- Design a board in KiCad
- Include fiducials if you can
- Make it real (mill it, laser-cut it, or get it fabricated using e.g. JLCPCB)
- Make a stencil (last-cut it, or get it included in your order)
- Export a
.posfile from your KiCad project- Go to
Place>Drill/Place File Origin - Click the lower-left corner of your board (or any place that’s easy to identify)
- Go to
File>Fabrication Outputs>Component Placement (.pos, .gbr) - Keep default settings (as of KiCad 10)
Format:Plain Text(orASCIIfor KiCad 9)Units:MillimetersUse drill/place file origin: check
- Go to
- Apply paste to your board using your stencil
- Use SAC305 paste in a syringe
- Place the stencil over your board and align it carefully
- Squeeze some paste over the opening
- Smooth it out (we have a squeege in 023, but you can also use a credit card)
- Make sure there is no paste left on the stencil and that you can’t see the pads on your board and get it on the flash drive at the LumenPnP station
- Set up the LumenPnP station
- Log into the PC. The password is
lumenpnp - Make super OpenPnP is not open
- If it is, close it
- Make sure all 3 of the USB cables from the LumenPnP are not plugged into the PC
- If they are, unplug them
- Make sure the LumenPnP is not plugged into the wall
- If it is, unplug it
- Plug the LumenPnP into the wall
- The barrel jack is on the right-hand side on the box under the plate
- Plug all three USB cables into the PC
- Use different ports
- Start OpenPnP
- It is the white icon on the bar on the left
- Start the LumenPnP using the Green “Power” button in the lower-left box
- If the machine hasn’t been used in a while and you have three hours to kill, calibrate
- The instructions for
v3.xare bookmarked in Firefox on that PC underCalibration
- The instructions for
- Log into the PC. The password is
- Follow the instructions at https://docs.opulo.io/openpnp/v4/ftp/
- This site is bookmarked in Firefox on that PC under
First Job - Use your
.posfile instead of theirftp-top.pos - Any instruction that applies to
R_0603_1608_Metric-R_Small, do for each of your unique components - You should be able to skip steps 1-3 (but not 4!) of the
Installing the N045 Nozzlesection (please leave that nozzle installed, please) - If you don’t have fiducials, skip the step where you mark fiducials as fiducials
- If you didn’t use the lower-left corner of your board for the drill/place origin, set the origin to whatever you used
- If you don’t have fiducials, don’t run a Fiducial Scan; instead use the button to the left of it and follow instructions
- Skip
Disable the LED components
- This site is bookmarked in Firefox on that PC under
- Reflow the board or blast it with hot air